Restoration Cert Lab · Free practical tool

Drying log builder

Build a repeatable job log that preserves material, meter mode and measurement location. Use comparable trends and environmental readings rather than treating every meter number as percent moisture.

Free results and workingNo signupLocal calculations
Your inputsCalculated on your device

Example values loaded. Replace them with your own measurements.

Drying measurements
Entry 1
Entry 2
Your result
↗

Make the numbers make sense.

Enter your values, choose the units, and calculate. You’ll see the result and the working here.

Free results. No account needed.

The method

Date-order measurements, preserve instrument/mode/material identity, and plot each comparable series separately.

Before using the result

  • This is a local worksheet. Findings and supplied criteria remain the responsibility of the person recording them; the output is not a certificate or regulatory approval.
  • Do not compare different meter scales as if they were equivalent physical moisture content.

Worked examples

These original training examples illustrate the method for IICRC Applied Structural Drying Technician (ASD). Use the matching “Load example” button above to explore a variation; example values are not equipment settings or prescribed criteria.

1. Worked example

Build a repeatable job log that preserves material, meter mode and measurement location. Use comparable trends and environmental readings rather than treating every meter number as percent moisture.

Supplied drying measurements
Measurement dateLocationMaterialInstrument IDMode / measurement methodReading on stated scaleInstrument reading unitAir temperature (°C)Air RH (%)
2026-10-01Wall AWoodMeter AWood scale24Instrument units2570
2026-10-03Wall AWoodMeter AWood scale18Instrument units2550
  1. Group readings by location, material, instrument, mode and unit.
  2. Compare trends only within the same series. An instrument scale is not automatically a moisture percentage.
  • Readings recorded: 2
  • Like-for-like series: 1

No drying target, microbial conclusion or cleaning threshold is inferred from these readings.

2. Comparison example

Compare a different supplied condition using the same method. For Restoration Cert Lab, the important check is that the input meaning, units and method assumptions still match the problem.

Supplied drying measurements
Measurement dateLocationMaterialInstrument IDMode / measurement methodReading on stated scaleInstrument reading unitAir temperature (°C)Air RH (%)
2026-10-01Wall AWoodMeter AWood scale30Instrument units2660
2026-10-03Wall AWoodMeter AWood scale22Instrument units2660
  1. Group readings by location, material, instrument, mode and unit.
  2. Compare trends only within the same series. An instrument scale is not automatically a moisture percentage.
  • Readings recorded: 2
  • Like-for-like series: 1

No drying target, microbial conclusion or cleaning threshold is inferred from these readings.

Check your understanding

1. Which relationship is used?

Date-order measurements, preserve instrument/mode/material identity, and plot each comparable series separately.

2. Which assumption should you check first?

This is a local worksheet. Findings and supplied criteria remain the responsibility of the person recording them; the output is not a certificate or regulatory approval.

3. How should you verify a different unit system?

Convert every input to the displayed calculation units first. Equivalent physical inputs must give equivalent results; a unit label alone does not convert a number.

Continue with the matching exam topic

This tool connects to IICRC Applied Structural Drying Technician (ASD) free practice. Work through a question independently, then use the calculation steps to identify where your method differs. The tool stays free whether or not you choose paid preparation.

Tool terms and notices